Skip to main content

Main menu

  • Home
  • Our journals
    • Clinical Medicine
    • Future Healthcare Journal
  • Subject collections
  • About the RCP
  • Contact us

Clinical Medicine Journal

  • ClinMed Home
  • Content
    • Current
    • Ahead of print
    • Archive
  • Author guidance
    • Instructions for authors
    • Submit online
  • About ClinMed
    • Scope
    • Editorial board
    • Policies
    • Information for reviewers
    • Advertising

User menu

  • Log in

Search

  • Advanced search
RCP Journals
Home
  • Log in
  • Home
  • Our journals
    • Clinical Medicine
    • Future Healthcare Journal
  • Subject collections
  • About the RCP
  • Contact us
Advanced

Clinical Medicine Journal

clinmedicine Logo
  • ClinMed Home
  • Content
    • Current
    • Ahead of print
    • Archive
  • Author guidance
    • Instructions for authors
    • Submit online
  • About ClinMed
    • Scope
    • Editorial board
    • Policies
    • Information for reviewers
    • Advertising

Use of an antiviral filter attached to a pleural drain bottle to prevent aerosol contamination with SARS-CoV-2

Mohammed R Akhtar, William Ricketts and Tim Fotheringham
Download PDF
DOI: https://doi.org/10.7861/clinmed.2020-0246
Clin Med July 2020
Mohammed R Akhtar
ABarts Health NHS Trust, London, UK
Roles: consultant interventional radiologist
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
William Ricketts
BBarts Health NHS Trust, London, UK
Roles: consultant chest physician
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: william.ricketts@nhs.net
Tim Fotheringham
ABarts Health NHS Trust, London, UK
Roles: consultant interventional radiologist
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

ABSTRACT

Pneumothoraces (1%) and pleural effusions (5%) are two of the less common complications of infection with COVID-19. Following a referral for a pleural drain insertion for a pneumothorax in a patient with COVID-19, we reassessed the infection risks involved in this procedure and its aftercare. Pleural drainage tubes attached to an underwater seal drain allow expulsion of aerosol and larger droplets via the vent from the bottle into the surrounding environment, potentially leading to infection of other patients and staff.

Consequently, we chose to attach an antiviral filter to the venting port of an underwater seal drain bottle to mitigate this risk. A fluorescein dye experiment was used to demonstrate the reduction in aerosol emission output from the bottle with our described technique, allowing an antiviral filter to be attached to a pleural underwater seal drainage bottle for added protection of patients and staff in the local environment.

KEYWORDS
  • Coronavirus
  • COVID-19
  • pneumothorax
  • chest drain
  • pleural

Pneumothoraces (1%) and pleural effusions (5%) are two of the less common complications of infection with COVID-19.1,2 Following a referral for a pleural drain insertion for a pneumothorax in a patient with COVID-19 (Fig 1), we reassessed the infection risks involved in this procedure and its aftercare. Pleural drainage tubes attached to an underwater seal drain allow expulsion of aerosol and larger droplets via the vent from the bottle into the surrounding environment, potentially leading to infection of other patients and staff.

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

Computed tomography prior to pneumothorax showing infiltrates in keeping with COVID-19 infection (a, b) and right upper lobe bulla (b), with pneumothorax immediately prior to (c) and immediately after (d) insertion of pleural drain.

Consequently, we chose to attach an antiviral filter to the venting port of an underwater seal drain bottle to mitigate this risk. The antiviral filter attached is a disposable filter from an anaesthetic machine rated at >99.99% filtration efficiency (Clear-Guard™ 3 breathing filter, Intersurgical Ltd). The filter was attached to 6 mm oxygen tubing using a straight 22 mm to 6 mm connector. Approximately 2.5 cm of oxygen tubing was used to attach the filter to the vent port on the drain bottle and secured with cable ties (Figs 2 and 3).

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

Components used to connect antiviral filter to the underwater seal vent. From left to right: cable ties, antiviral filter (Clear-Guard™ 3 breathing filter, 1544000, Intersurgical Ltd), straight connector 22F to 6 mm oxygen stem (15680000, Intersurgical Ltd) and oxygen tubing.

Fig 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 3.

Underwater seal drain bottle (R54500 Rocket blue single bottle system, Rocket Medical) connected to the antiviral filter.

To demonstrate the reduction in aerosol emission output from the bottle, 1 g of fluorescein dye was added to 500 mL of water in a standard underwater seal drain bottle. The pleural drain was connected to room air at a flow rate of 5 L/min. A black card was placed 3 cm above the bottle vent and photographed under a UV light after 2 hours. The experiment was repeated without and with the filter attached, and photographs taken demonstrate aerosol emissions and droplets from the drain bottle when the filter is not used (Fig 4).

Fig 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 4.

Fluorescein dye expelled from an underwater seal drain vent onto black card 3 cm above the vent.

Possible aerosol contamination from a pleural underwater seal drain merits further investigation. A significant proportion of COVID-19 patients are on higher oxygen requirements or positive pressure ventilation with the pleural drain in situ for longer than the 2 hours we allowed for in our simulation, leading to potentially even greater aerosol loads being generated. This simulation was not validated for speed or size of particles expelled through the venting port. Despite this, our described technique, which utilises disposable equipment that is readily available, allows an antiviral filter to be attached to a pleural underwater seal drainage bottle for added protection of patients and staff in the local environment.

  • © Royal College of Physicians 2020. All rights reserved.

References

  1. ↵
    1. Shi H
    , Han X, Nanchuan J, et al. Radiological findings from 81 patients with COVID-19 pneumonia in Wuhan, China: a descriptive study. Lancet Infect Dis 2020;20:425–34.
    OpenUrlPubMed
  2. ↵
    1. Chen N
    , Zhou M, Dong X, et al. Epidemiological and clinical characteristics of 99 cases of 2019 novel coronavirus pneumonia in Wuhan, China: a descriptive study. Lancet 2020;395:507–13.
    OpenUrlCrossRefPubMed
View Abstract
Back to top
Previous articleNext article

Article Tools

Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Citation Tools
Use of an antiviral filter attached to a pleural drain bottle to prevent aerosol contamination with SARS-CoV-2
Mohammed R Akhtar, William Ricketts, Tim Fotheringham
Clinical Medicine Jul 2020, 20 (4) e60-e61; DOI: 10.7861/clinmed.2020-0246

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Use of an antiviral filter attached to a pleural drain bottle to prevent aerosol contamination with SARS-CoV-2
Mohammed R Akhtar, William Ricketts, Tim Fotheringham
Clinical Medicine Jul 2020, 20 (4) e60-e61; DOI: 10.7861/clinmed.2020-0246
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • ABSTRACT
    • References
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • COVID-19 and pneumothorax: a multicentre retrospective case series
  • Chest drain aerosol generation in COVID-19 and emission reduction using a simple anti-viral filter
  • COVID-19 viral expulsion through chest drains
  • Google Scholar

More in this TOC Section

  • Autonomic dysfunction in ‘long COVID’: rationale, physiology and management strategies
  • Preventing vitamin D deficiency during the COVID-19 pandemic: UK definitions of vitamin D sufficiency and recommended supplement dose are set too low
  • Requests from primary care for chest X-ray and CA125 measurements during the COVID-19 emergency: An observational study
Show more COVID-19 rapid report

Similar Articles

Navigate this Journal

  • Journal Home
  • Current Issue
  • Ahead of Print
  • Archive

Related Links

  • ClinMed - Home
  • FHJ - Home
clinmedicine Footer Logo
  • Home
  • Journals
  • Contact us
  • Advertise
HighWire Press, Inc.

Follow Us:

  • Follow HighWire Origins on Twitter
  • Visit HighWire Origins on Facebook

Copyright © 2020 by the Royal College of Physicians