Focus Issue: Valvular Heart Disease
Clinical Research
A New Transcatheter Aortic Valve and Percutaneous Valve Delivery System

https://doi.org/10.1016/j.jacc.2008.07.075Get rights and content
Under an Elsevier user license
open archive

Objectives

We describe procedural and clinical outcomes in a high-risk cohort undergoing transcatheter aortic valve replacement with early next-generation transcatheter valve and delivery systems.

Background

Percutaneous aortic valve replacement is gaining acceptance as a viable option in patients at high surgical risk. Broader application will require further advances in valve and delivery system technology.

Methods

Transarterial aortic valve replacement was attempted in 25 patients (mean age 85 years) determined to be at high surgical risk due to comorbidities. A new delivery catheter system (RetroFlex 2, Edwards Lifesciences, Irving, California) was utilized in combination with either a balloon-expandable SAPIEN (Edwards Lifesciences) valve or a next-generation low-profile cobalt-chromium bovine pericardial SAPIEN XT (Edwards Lifesciences) valve.

Results

Percutaneous valve replacement was successful in all 25 high-risk patients. Aortic valve area increased from 0.59 ± 0.15 cm2to 1.60 ± 0.27 cm2. In this high-risk cohort (Society of Thoracic Surgeons and logistic EuroSCORE estimates of surgical mortality were 8.9% and 21.0%, respectively), 30-day mortality was 0%.

Conclusions

Technical and procedural advances in catheter systems and prosthetic valves designed for percutaneous aortic valve delivery may contribute to increased procedural success and improved clinical outcomes.

Key Words

aortic stenosis
percutaneous
valve
valvuloplasty

Abbreviations and Acronyms

AVR
aortic valve replacement
IQR
interquartile range

Cited by (0)

Dr. Webb is a consultant to Edwards Lifesciences Inc.