Abstract
Simulators may be used in training personnel for the situations when consequences of inappropriate action could be dangerous or expensive. Mishaps, and accidents in connection with the use of biomedical instrumentation are frequently a result of technical malfunction and improper use of the equipment. In the medical field, however, use of simulators is not very common.
This paper reports our experiences of a development project to design the ‘PatSim’ hands-on simulator for training anaesthesia and intensive care personnel. The simulator consists of a manikin positioned on an operation table or in a typical critical care bed. The manikin, which is controlled by a standard personal computer (PC), can be ventilated by an anaesthesia machine or a ventilator, intravenous pumps can also be connected. Any standard electrodes and transducers can be used to pick up parameters, like ECG, invasive and non-invasive blood pressure, airway pressure and CO2. Data can be displayed on any monitor or workstation. There is no need for modification or special adaptation of the medical equipment used in the simulation scenario.
The manikin is capable of spontaneous breathing. Controlled from the PC, different clinical signs can be developed. In addition, typical clinical symptoms can be created during the simulated treatment period. They include laryngospasm, change of lung compliance or airway resistance, pneumothorax, leakage of the intubation tube cuff, blocking of the breathing sounds from one lung, secretion, gastric regurgitation and diuresis. During a simulation session, the trainee should be exposed to a lifelike situation. Hence, we place the manikin in a room that resembles either intensive care or operating room environment.
Article PDF
Similar content being viewed by others
References
Andrews DH. Relationships among simulators, training devices, and learning: a behavioural view. Educ Tech 1988; 28: 48–54.
Schwid HA. Flight Simulator for General Anaesthesia Training. Comp and Biomed Res 1987; 20: 64–75.
Abrahamson S. Human simulation for training in anesthesiology. Medical Engineering. Year Book Medical Publishers, Inc. 1974; 370–374.
Good ML, Gravenstein JS. Anesthesia simulators and training devices. Int Anesthesiology Clinics 1989; 3: 161–166.
Gaba DM, DeAnda A. A Comprehensive Anaesthesia Simulation Environment: Re-creating the Operating Room for Research and Training. Anesthesiology 1988; 69: 387–394.
Chopra V, Engbers FHM, Geerts MJ, Filet WR, Bovill JG, Spierdijk. The Leiden anaesthesia simulator. British J of Anaesthesia 1994; 73: 287–292.
Jensen PF, Andersen HB, Nielsen FR and Pedersen SA. The Anaesthesia Simulator Sophus. Risoe Report. Risoe-R-718. ISBN 87-550-1940-4.
Olufsen M, Nielsen F, Jensen PF, Pedersen SA. The models underlying the anaesthesia simulator Sophus. R.U.C. Report 278/94. Roskilde University Center.
Berge JA, Gramstad L, Jensen Ø. A training simulator for detecting equipment failure in anaesthetic machine. European J of Anaesth 1993; 10: 19–24.
Rettedal A, Freyer S. Patient Simulator for training the Use of Ventilators. Proc. of North Sea Conf on Biomedical Engineering, Antwerp 19–22, Nov. 1990.
Azinfar H, Ruud M. Korotkofflyd generator, Thesis, Clinical Engineering, Stavanger College, 1994.
Swank KM, Jahr JS. The uses of simulation in anestesiology training. J La State Med Soc, Vol. 144, 1992; 11: 523–527.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Arne, R., Ståle, F., Ragna, K. et al. PatSim—Simulator for practising anaesthesia and intensive care. J Clin Monit Comput 13, 147–152 (1996). https://doi.org/10.1023/A:1016964810485
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1023/A:1016964810485