A project identifying potential risk factors leading to diabetic ketoacidosis in patients with type 1 diabetes treated with an insulin pump
Diabetic ketoacidosis (DKA) is a life threatening condition in people with type 1 diabetes (T1D).1 With 10–30% of people in developed countries on insulin pump therapy for managing T1D, DKA in such patients can result in fatal or near-fatal consequences.2–4 Despite its severity, there is no reporting process for its frequency in those on pump therapy, thus we have undertaken an audit to analyse potential risk factors leading to DKA admissions. The aim was to retrospectively review a cohort of adult T1D patients established on an insulin pump (for a minimum of 4 years), who had been admitted with DKA in the preceding 3 years (2017–2019). Key clinical features such as the patients’ glycated haemoglobin (HbA1c) prior to admission and the time since last being seen in clinic were analysed, alongside metabolic parameters, to try and pinpoint critical warning signs to indicate increased risk of DKA in these individuals. Data collection also incorporated variables on admission including glucose levels, pH and ketones. Episodes of DKA arising from 11 patients were analysed (some patients had multiple episodes). In the episodes for which full data were available, the overall mean lowest pH during admission was 7.23. The median time since the patients’ last visit to the clinic was 4.5 months. We compared the clinical data during the index admission of these patients seen before and after 4.5 months, in Table 1, showing increased severity in those with a longer duration from the last clinic. Potential causes of DKA included infection, pump failure and other pathologies. There were several strong positive correlations found: the last HbA1c measurement and the time since the last visit to the clinic (r = 0.597), the number of missed clinic visits in the study period and the maximum ketones on admission (r = 0.654), the last HbA1c measurement and the maximum ketones during admission (r = 0.666). Comparison of the most recent HbA1c in the DKA cohort (82.9 mmol/mol) versus an equivalent pump cohort who did not experience DKA (60.5 mmol/mol), showed there was a significant difference using a Mann–Whitney U test (p<0.05).
Discussion
Our data show that a significant number of DKA episodes occurred in patients established on insulin pumps. Within this group, HbA1c levels were, on average, very high and higher than the pump cohort in general. We can also conclude that, as suggested by the several strong positive correlations, not attending clinics or having less frequent contact with the diabetes team could be linked to severity in some DKA admissions. These data show that more focused management for patients established on pumps with highly elevated HbA1c, in addition to clearer future planning for reviewing pump therapy (including so-called ‘pump holidays’), could be required. The presence of risk factors for DKA in insulin pump users illustrates that with an increasing number of such patients, including those in hospital, detailed multidisciplinary review systems must be embedded to optimise clinical outcomes.5
- © Royal College of Physicians 2020. All rights reserved.
References
- ↵
- Farsani S
- ↵
- Tikander E
- Junichi S
- ↵
- Ziegler A
- ↵
- Anstey J
Article Tools
Citation Manager Formats
Jump to section
Related Articles
- No related articles found.
Cited By...
- No citing articles found.